Acoustic materials manufacturer · Foshan, China
Black floor vibration isolation bricks
Damping rubber · floating-floor vibration isolation

Floor Vibration Isolation Bricks

Dense, resilient support blocks for decoupling a floating floor from the structural slab, reducing impact vibration and carrying the layered floor above.

Module
150 × 150 mm
Thickness
50 mm
Material
Damping rubber granules
Resilient load-bearing support

Separate the floor from the structure at the points that carry it.

Each brick forms a controlled resilient support beneath the floating layer. Installed as an engineered grid, the bricks help limit direct vibration paths while leaving space for acoustic infill and building services.

Impact-vibration controlStrong load supportModular grid installationFloor-system compatible
Product specification

A compact module for complete floating-floor assemblies.

The finished acoustic result depends on the whole construction: brick spacing, imposed load, absorptive infill, perimeter separation, load-spreading layers and junction sealing. Confirm the complete floor build-up before ordering.

150 × 150Module size, mm
50 mmBrick thickness
RubberHigh-polymer damping granules
GridProject-specific support layout
System roles

Three jobs inside one resilient floor support.

The brick is designed as a structural-acoustic component, not a decorative finish. Its value comes from how it works with the surrounding layers.

01Isolate

Vibration separation

The resilient material helps interrupt rigid transmission paths between the floating floor and base slab.

02Support

Load distribution

A regular engineered grid supports the load-spreading layer across the complete floor area.

03Coordinate

Modular layout

The 150 mm module can be arranged around edges, services and room geometry to suit the specified system.

Build the bricks into a complete floating-floor isolation assembly.

Final acoustic performance depends on the structural slab, support grid, cavity infill, resilient perimeter, load-spreading layers, penetrations and floor finish.

Exploded floating-floor acoustic isolation system
01

Floating-floor isolation system

Combine the bricks with resilient perimeter separation, absorptive infill and a continuous load-spreading layer to decouple the occupied floor from the structural slab.

  1. Floor finish
  2. Load-spreading board or screed
  3. Acoustic infill
  4. Isolation bricks
  5. Structural slab
Installers assembling the isolated floor and absorptive infill
02

Brick and infill layout

Set the support spacing to the project load and board system, then fill the field without creating rigid bridges between the floating layer and the surrounding structure.

  1. Engineered support spacing
  2. Continuous acoustic infill
  3. Separated perimeter
  4. Coordinated services
Load-spreading panels closing the floating-floor system
03

Load-spreading finish

Close the system with the specified board, screed and finish layers so loads are distributed across the resilient support grid while edge separation remains continuous.

  1. Staggered board joints
  2. Distributed floor load
  3. Sealed penetrations
  4. Continuous edge isolation
Installation principles

Lay out, isolate, infill and close.

Support spacing and the upper floor construction must be designed for the project load. Keep the floating layer separated from walls, columns, pipes and other rigid junctions.

01SurveyConfirm floor level, design load, service routes, edge conditions and the required finished height.
02Set outMark the engineered support grid and place each brick flat on a clean, stable structural slab.
03InfillFit the specified acoustic cotton or insulation between supports without blocking the resilient action.
04CloseInstall the separating layer, load-spreading boards or screed, sealed perimeter and final floor finish.
Installed projects

From support grid to finished floating floor.

The supplied project photographs show brick positions, absorptive infill, separating layers and closing boards at different stages of construction.

Large floating-floor area prepared with vibration isolation bricks and acoustic infill
Project viewLarge-area isolation layout
Close view of modular floor panels with black vibration isolation supports
Layout detailRegular support grid
Floor vibration isolation system being prepared before acoustic infill is completed
Construction stageSystem preparation
Installers placing the separating layer over an isolated floor with absorptive infill
InstallationFloating-floor build-up
Load-spreading floor boards installed above the vibration isolation grid
Closing stageLoad-spreading layer
Applications

For floors exposed to impact, music and equipment vibration.

KTV roomsBars and clubsCinemasRecording studiosHotelsOfficesResidential roomsEquipment rooms
Talk to our export team

Need a floating-floor isolation layout?

Send us the room dimensions, design load, base slab, target floor height, upper floor construction and destination. We will quote the 150 × 150 × 50 mm brick and help coordinate an appropriate assembly direction.