Ground Shock Absorber Pads
High-density polyurethane-rubber pads that create a resilient break beneath floating floors, helping control impact noise and structure-borne vibration.
- Thickness
- 2–20 mm standard
- Width
- 1 m roll format
- Options
- Black / multicolor
Create a resilient break beneath the complete finished floor.
The dense elastic layer sits between the structural slab and the upper floor build-up. Its continuous coverage helps reduce direct vibration paths while supporting a coordinated floating-floor system.
Durable polyurethane-rubber formats for project floors.
Standard thicknesses cover common underfloor requirements, with other dimensions and performance options available after project confirmation. Final acoustic performance depends on the complete tested floor assembly.
One continuous layer, three essential functions.
Specify the pad as part of a complete floor build-up according to imposed load, finish type, available height and required vibration control.
Resilient separation
The elastic layer interrupts direct contact between the upper floor construction and the base slab.
Moisture and wear resistance
The dense rubber structure is suitable for concealed underfloor service and repeated construction handling.
Project-specific formats
Black and multicolor options, standard 2–20 mm thicknesses and custom formats support different build-ups.
Build the pads into a complete floating-floor isolation assembly.
Final performance depends on pad continuity, perimeter isolation, junction sealing, reinforcement, the load-spreading layer and the selected floor finish.

Continuous resilient layer
Lay the pads across a clean, stable slab with tight joints to form a continuous break beneath the floating floor.
- Prepared structural slab
- Tight pad joints
- Continuous coverage
- Separated perimeter

Load-spreading screed
Protect the resilient layer, coordinate reinforcement where required and place the screed without creating rigid bridges to the structure.
- Protective separation layer
- Reinforcement where specified
- Load-spreading screed
- Isolated junctions

Finished floor build-up
Install the selected dry board, screed or floor finish above the resilient pad while maintaining edge separation around the whole room.
- Floor finish
- Load-spreading layer
- Resilient pad
- Structural slab
Prepare, cover, isolate and close.
Keep the resilient layer continuous and prevent the upper floor from making rigid contact with walls, columns, pipes, thresholds or other structural elements.
From resilient underlay to finished floating floor.
The supplied project images show rollout, reinforced screed installation and a finished timber floor over the resilient pad.



For occupied floors exposed to impact and vibration.
Need a resilient floor-pad specification?
Send us the room area, design load, base slab, target floor height, selected finish and required thickness. We will recommend an appropriate pad format and help coordinate the floating-floor build-up.